On this page
Choose a fan that can deliver the required airflow through your actual duct and outlet. Check applicable local requirements and how air will enter the room while the door is closed. Fan diameter and catalogue airflow alone are not enough to specify an installation.
This guide is written for South Africa. Always check local codes, product specifications, licences, and site conditions.
Step by step
Measure the room and describe how it is used
Write down the room length, width and ceiling height, together with the position of the shower, window and door. A room volume gives context but cannot replace an applicable minimum flow requirement. Ask whether the fan will run intermittently with a timer or continuously as part of a whole-home system. Record times when mirrors or walls remain wet and whether the bathroom is frequently used by several people in succession. Distinguish surface condensation from a leak behind tiles or around plumbing. Ask the installer to identify the required flow and any installation rules for the property before making a shortlist.
Compare airflow figures in matching units
Manufacturers may list airflow in litres per second or cubic metres per hour. Multiply litres per second by 3.6 to convert to cubic metres per hour. For example, 20 litres per second equals 72 cubic metres per hour. This conversion is an example, not a recommendation for every bathroom. Note whether quoted performance is measured with little resistance or at a stated pressure. A fan that moves enough air in open testing may deliver less after a duct, a grille and a backdraught shutter are fitted. Ask for performance under the expected installation conditions and compare only figures that refer to similar conditions.
Plan the whole route to the outside
Sketch the proposed opening and the position of the outside terminal. Record bends, changes in diameter and duct length. Show the sketch to the installer and confirm which fan type and duct size suit that route. A grille, shutter or compressed flexible duct can impose resistance and affect noise. Do not discharge moist air into a roof space or wall cavity. Check access for cleaning, how the terminal will handle weather and whether condensation in the duct needs attention. If mounting requires cutting a structure or altering a shared exterior wall, confirm permissions and have the details checked before opening the surface.
Consider replacement air, noise and safe controls
The removed air must be replaced. Ask how it will enter while the bathroom door is closed and which options preserve fire, acoustic and privacy requirements. Avoid modifying a door or grille before checking what else that detail does. Choose controls that suit the household, such as a timer or an appropriate humidity control, and ask how they should be adjusted. Bathroom electrical positioning and equipment selection need an appropriately qualified installer. Make sure the equipment is intended for its actual location and exposure. Discuss noise alongside performance so people are more likely to use the fan long enough for it to help.
Verify the fan once it is installed
Ask the installer to verify delivered performance where required and explain the operating and cleaning schedule. Check that the outside terminal is open and that the control behaves as expected. After ordinary shower use, watch whether condensation clears sooner under comparable conditions. Persistent damp can also reflect cold surfaces, insufficient background ventilation or a hidden leak. A tissue held near a grille can suggest direction of air movement but does not establish airflow or compliance. Keep the installed model, setting and documentation so a replacement can be chosen using the actual system rather than a guess about the original fan.
Expert tips
- Check the relevant South African requirements with the installer. Overseas worked examples should not be applied as local regulatory figures.
- Compare a quiet normal setting as well as maximum airflow. Maintenance access matters because dust and dirty grilles can reduce performance.
Common questions
Is a 100 mm fan always enough?+
The diameter describes the connection, not the delivered airflow. Match the product and duct to the project’s requirements.
Should I choose a timer or a humidity sensor?+
That depends on occupancy, ventilation strategy and how the equipment is used. Ask the installer how each control will behave in the room.
Can I use the roof space as an outlet?+
Route the extract to an appropriate outside terminal. Releasing moisture into an enclosed cavity can create damp elsewhere.
Sources & further reading
We link to official building-code, government and public-health material where a technical or safety claim needs authoritative context. Local rules and adopted code editions can change.
Stop if the work involves structural uncertainty, hazardous materials, heights, live services, gas, serious water damage, or regulated work. Local rules differ—use an appropriately licensed professional where required.