Measure the old door leaf and the opening inside its lining separately. Take width at the top, middle and bottom, then height from finished floor at both sides and the centre. Record leaf thickness, lining depth and the swing. Ask the supplier to confirm the door size and permissible trimming. Refer any fire door to a qualified specialist.

Regional note

This guide is written for United Kingdom. Always check local codes, product specifications, licences, and site conditions. Browse the United Kingdom edition.

Preparation

Measurements to bring to a supplier

Start with a tape, a sketch and an identifiable door location.

  • Existing leaf height, width and thickness, in millimetres.
  • Clear opening measurements at three positions, wall thickness where visible and the finished floor level.
  • Photographs of the lining stops, hinges, threshold, latch and any certification marks.
The method

Step by step

01

Choose whether the lining is staying

The leaf is the moving panel. The lining is the frame and its associated stops against which the leaf closes. Architrave is the trim around that assembly. If all you need is a new leaf, check the inside dimensions of the existing lining. If the lining is also being replaced, the structural opening and finished wall thickness become relevant. They may be hidden behind the architrave. Treat concealed dimensions as unknown until the person fitting the door can confirm them. Before buying anything, identify whether the door might be fire rated or part of a protected route. Leave uncertain doors and their fittings to a qualified specialist.

02

Measure the existing leaf without inferring its nominal size

With the door accessible, record the width near the top, centre and bottom and note if it tapers. Measure both long edges for height and the thickness at a plain location clear of hardware. Make a sketch that identifies the hinge side and the direction the door opens. Note where it currently catches, closes easily or has a noticeably uneven gap. Existing leaf size is helpful because it shows what has fitted before, but a door can be distorted, trimmed or badly fitted. If the present leaf no longer closes, bring the frame dimensions as well to explain the reason you are replacing it.

03

Measure the lining in its working plane

Take three measurements across the inside of the lining where the leaf sits, avoiding measuring the decorative opening at a different depth. Measure from the finished floor to the top of the opening on each side and through the middle. Add diagonal measurements if you can measure reliably from matching corner points. A difference between diagonals is a reason to investigate the shape rather than just ordering a smaller leaf. Note the lining depth at a visible edge and label which wall surfaces were included. If new carpet and underlay are proposed, photograph the proposed finish stack and mark that the recorded floor is temporary.

04

Read a set of dimensions before ordering

Suppose an existing leaf measures 762 mm wide and the inside of its lining measures 768 mm at the top, 766 mm in the middle and 764 mm at the bottom. The available total side clearance would vary from 6 mm to 2 mm if a 762 mm leaf sat in that opening. Those numbers identify a tight spot to discuss. They do not tell you how much to cut. Find the candidate door’s approved trimming limits for each edge and ask whether the lining needs attention instead. A nominal match to a 762 mm shelf label does not settle the fit when the lining narrows.

05

Turn the sketch into a clear ordering question

Give the supplier a clean set of readings and say whether the old lining remains. Confirm the exact product dimensions and thickness. Ask whether any floor clearance, threshold detail or necessary accessibility performance changes the choice. If a lining kit is required, ask which finished wall thickness and leaf sizes it suits and where hidden structural dimensions must be confirmed. Record the hardware requirements rather than assuming the old hinge recesses and handle positions will transfer. For rented or leasehold property, confirm permissions and any fire-safety instructions before changing parts. Keep the final product code and the confirmed measurements together.

Before you start

Expert tips

  • Photograph the tape reading next to the doorway and name the room and side in each image.
  • Bring the tightest reading and all individual readings. Averages hide a tapered lining.
  • Confirm any planned floor replacement before relying on today's height readings.
People also ask

Common questions

Can I buy a replacement based only on the old door width?+

Use that as a product search clue. The lining dimensions, finished height and leaf thickness can rule out a candidate with the same width. Verify the smallest openings and the candidate’s trimming instructions.

What happens if a door has a fire label or closer?+

Stop and obtain specialist advice. This guide is for ordinary internal doors. Fire performance depends on the specified assembly, hardware and fitting, and requirements vary by building and jurisdiction.

Do I measure wall thickness across the architrave?+

Record the actual finished wall depth where it can be seen and identify your reference points. An external trim measurement may include projections that are irrelevant to the lining kit.

Primary references

Sources & further reading

We link to official building-code, government and public-health material where a technical or safety claim needs authoritative context. Local rules and adopted code editions can change.

  1. WickesInternal door measuring overviewUK retailer measuring guidance for standard internal doors.
  2. GOV.UKFire door guidance in EnglandEngland-specific context. Consult the local authority and a competent specialist for the property.
!
Know your limit

Stop if the work involves structural uncertainty, hazardous materials, heights, live services, gas, serious water damage, or regulated work. Local rules differ—use an appropriately licensed professional where required.