On this page
Record the width and the length a carpet follows over each tread, nosing and riser. Count the steps and measure the landing separately. For a straight flight, these figures make a useful estimate. Ask the fitter to confirm how the carpet will be cut, especially around edges, patterns, winders and changes in pile direction.
This guide is written for United Kingdom. Always check local codes, product specifications, licences, and site conditions. Browse the United Kingdom edition.
Keep the stairs safe during measuring
This is a quantity survey, not a fitting guide. Use secure footing, keep a handrail available and avoid loose materials on a route.
- A measuring tape for flat dimensions, a flexible measure for the carpet path and a step-by-step sketch.
- Chosen carpet details including width, pattern repeat and the proposed runner or full-width coverage.
- Photographs of turns, balusters, unusual edges or damage that the fitter should see.
Step by step
Confirm the layout and identify unusual steps
Sketch the run from the bottom to the landing and give each visible step a number. A tread is the surface underfoot, a riser is the face between treads and a nosing is the front edge or projection. Note where the last riser meets the upper landing and whether a door or another flight interrupts the carpet route. If a step turns into a wedge-shaped winder or changes width, draw its position and let the fitter survey it rather than averaging it with straight steps. Check the stairs are usable and sound. Tell the fitter about any loose nosing or tread before measuring nearby.
Measure the path the carpet actually takes
At a safe position, record the usable clear width across the step and note any projecting trim or features that would affect cutting. Measure along the path of the finish over tread, nosing and riser according to the fitter’s method. Avoid counting a rounded edge twice if the tape already follows it. A simple horizontal run and a vertical rise help check the arithmetic, but a nosing can change what the covering needs. Measure the first and last steps separately. Check more than one step before relying on a repeated dimension. Do not carry a stretched tape across the flight while someone is using it.
Measure landings and transitions separately
Record the widest and longest clear parts of each landing and mark recesses, doorway thresholds and the approach to the stairs. Give the fitter your desired carpet line at doors rather than treating the far wall as the only endpoint. A landing join and the carpet direction at the top step affect how pieces can be cut. Pattern matching may add material. If you are comparing carpet rolls or remnants, note the product width and direction without assuming any offcut can turn through ninety degrees. Ask how the fitter will handle the first transition as well as the upper one.
Use a twelve-step example to check order of magnitude
Imagine 12 straight steps with a measured carpet path of 460 mm each and a clear width of 850 mm. A continuous 850 mm-wide runner blank following those paths would use 12 × 460 mm, or 5.52 metres, before the fitter’s allowances. This figure illustrates the run only. It excludes finishing at the bottom, continuity at the top, the landing, trimming and any carpet-specific fitting requirements. A broadloom carpet may be cut from a wider roll instead of ordered as an 850 mm-wide length. Give the fitter your numbered sketch so they can decide how roll width and pile direction affect the actual buying quantity.
Make the quote and the installation checks specific
Ask the fitter to verify the survey before you buy a non-returnable length. Have them show what the quote includes: widths, length, top landing, underlay, profiles, edge finishing and work to unsafe or damaged parts. Tell them whether you chose a runner or a full stair covering and how any exposed margins should look. Keep the cutting diagram where it shows a pattern repeat or offcut. On handover check the stairs are secure, continuous at key transitions and free of raised edges. Record the carpet product and dye batch if available so any later replacement can be assessed against the same specification.
Expert tips
- Number any different-sized step rather than rounding it into the flight total.
- Record the same units throughout. Sketches are easier to check when length and width are also labelled.
- Get a fitter’s measure before ordering patterned flooring.
Common questions
Can I buy from the total square metres alone?+
No. A fitter needs the roll width, pile direction, drop lengths, turns and joins. Two layouts with equal area can need different buying quantities.
Can I use the same length for every step?+
Only when your checks show the relevant measurements really repeat. Mark each exception and have the fitter confirm the final cut plan.
Does the top landing change the stair length I buy?+
It may affect the transition and the way the top step is cut. Give the fitter separate landing dimensions, adjacent doorway details and your chosen carpet.
Sources & further reading
We link to official building-code, government and public-health material where a technical or safety claim needs authoritative context. Local rules and adopted code editions can change.
Stop if the work involves structural uncertainty, hazardous materials, heights, live services, gas, serious water damage, or regulated work. Local rules differ—use an appropriately licensed professional where required.