THE SHORT ANSWER

Draw the room and test accessible skirting joints with a light tissue strip while the room is in normal use. Record where the tissue moves, then repeat under similar weather conditions. Keep purpose-made vents and unknown openings clear. Persistent damp, combustion appliances or hidden cavities are reasons to ask a competent professional before sealing.

Preparation

Set up an observation log

A cold edge or a moving tissue gives a clue. Record the conditions so you can see whether the effect is repeatable.

  • Room sketch, pencil, dated photographs and several narrow strips of tissue.
  • A note of wind direction if known, fan and heating status, and whether nearby windows and doors are open.
  • Labels for visible vents, grilles, door undercuts and floor transitions that may serve a purpose.
The method

Step by step

01

Start with what could intentionally move air

Walk around the room and find trickle vents, transfer grilles, under-door paths, return grilles and visible airbricks accessible from outside ground level. Mark them on the sketch. An opening in one surface can connect to a floor or wall void somewhere else. Leave it untouched unless you know its purpose. If there is a fuel-burning appliance or an open fireplace, note it and leave the air arrangement as designed. An assessment can determine whether air is needed for combustion and whether ventilation will remain adequate after any work. Avoid disabling fans or creating unusual pressure differences to make a leak easier to find.

02

Gather simple observations at skirting height

Start in a comfortable part of the room and then compare the wall where you feel the cold. Hold a narrow, loose strip of tissue beside the top of the skirting, the bottom edge and visible corners. Keep it clear of moving fan blades, flames, heaters and electrical fittings. Use the same distance each time so readings are comparable. Label movement as none, intermittent or persistent. Avoid candles, incense or other smoke. Test beside the trim without inserting a probe, removing covers or lifting boards. Photograph any dark mark, loose trim, staining or changes in flooring rather than assuming it is an air leak.

03

Tell incoming air from other reasons for a cold floor

A wall or floor can feel cold without a strong movement of outside air. Cold air can fall from glazing and move along the floor, or a heater outlet can push room air past your feet. Compare the suspect joint with a similar area away from the window and look for movement that consistently starts at one edge. Repeat with the house used normally, rather than moving every opening and fan at once. Note that calm weather can hide a leak and windy weather can produce brief reversals. Condensation, mould, swelling or water staining calls for a moisture check alongside any draught investigation.

04

Turn the readings into a useful repair brief

Suppose a 3.8 m outside wall feels cold. The tissue moves repeatedly over a 400 mm section at the corner, stays still along the next two metres, and moves beside a floor grille at the other end. Record those three observations separately. A suspected leak at the corner can be investigated while the grille stays clear, and any reading near the grille needs its own interpretation. Mark the nearest reference, such as 200 mm from the sill return. Repeat the sketch on a different day. A fitter or energy assessor can then check the likely route without sealing the entire perimeter on a hunch.

05

Decide what can safely be corrected and recheck

Look up the floor and trim system before asking someone to fill a gap. Floating floors may need their perimeter movement space. A gap behind loose trim, an opening into a damp void and a deliberate movement joint need different approaches. For multiple leaks, unexplained smells, recurring damp or air movement near an appliance, ask a qualified specialist about the envelope and ventilation together. If authorised work is carried out, repeat your original test and keep the same conditions as far as practical. Check that vents still operate and doors still move freely. Record any new problem so it can be investigated while the repair details are known.

Before you start

Expert tips

  • A repeatable point on the sketch is more useful than reporting that the whole room feels draughty.
  • Separate the weather and airflow observations from your theory about the source.
  • Leave a breathing or drainage opening clear until you have identified what it serves.
People also ask

Common questions

Can I caulk between the skirting and laminate?+

Check the floor manufacturer’s movement and finishing requirements first. Many floating floors need an edge gap and must stay free to move. Have the real air path checked before altering that detail.

Why does the draught seem stronger when a fan runs?+

Fans can change pressure and send air along different routes. Note the normal fan state in your log. Repeated airflow at a spot still needs interpretation, especially near purpose-made ventilation or appliances.

Should I block an airbrick that makes a room cold?+

Keep it clear until a competent person identifies what it does. A grille or airbrick can serve the room, floor void or an appliance. Blocking it may interfere with ventilation or moisture management.

Primary references

Sources & further reading

We link to official building-code, government and public-health material where a technical or safety claim needs authoritative context. Local rules and adopted code editions can change.

  1. ENERGY STARLocating air leaksExplains common envelope leak paths and why the visible draught can be separate from the primary leak.
  2. US Environmental Protection AgencyEnergy, weatherization and indoor air qualityDiscusses treating air sealing and ventilation together when improving a house.
!
Know your limit

Stop if the work involves structural uncertainty, hazardous materials, heights, live services, gas, serious water damage, or regulated work. Local rules differ—use an appropriately licensed professional where required.